    • Abstract:
      Introduction. In order to minimize the required time to regain esthetic and function, immediately loaded implants were suggested. The aim of this study was to comparatively evaluate the Nisastan and XIve implants using biomechanical and histomorphometric tests. Materials and Methods. In this experimental study, 6 Nisastan one-piece immediately loaded screw type implant (OPILS) and 6 Xive implants with 3.4mm diameter and 11mm long were used. The implants were immediately loaded with temporary coating. After three months, the torque required to break bone-implant contact was measured and was recorded. All implants were extracted with surrounding bone and histologically were evaluated. The data were inputted into the SPSS 11.5 to run student T-test statistical analyses (a = 0.05). Results. The success rates of both types of implants was 100%, and none of them failed due to mobility or bone loss. Themean removal torque value (RTV) was 142.08 and 40N/Cm for Xive and Nisastan implants, respectively, and their RTVs showed a significant difference between two mentioned implants (P = 0.004). None of the histomorphometric values showed significant differences between the two implants (P > 0.05). Discussion. both systems have the capability to induce osseointegration under immediate loads but that Xive implants showed higher capability for bone contact. [ABSTRACT FROM AUTHOR]
    • :
      Copyright of ISRN Dentistry is the property of Hindawi Limited and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
    • Author Affiliations:
      1Dental Implant Research Center and Prosthodontics Department, Dental School, Isfahan University of Medical Sciences, Hezarjerib Street, Isfahan 8174673461, Iran
      2Torabinejad Dental Research Center and Oral and Maxillofacial Surgery Department, Dental School, Isfahan University of Medical Sciences, Hezarjerib Street, Isfahan 8174673461, Iran
      3Dental Implant Research Center, Dental School, Isfahan University of Medical Sciences, Hezarjerib Street, Isfahan 8174673461, Iran
      4Torabinejad Dental Research Center and Oral Pathology, Dental School, Isfahan University of Medical Sciences, Hezarjerib Street, Isfahan 8174673461, Iran
      5Dentistry Department, Dental School, Isfahan University of Medical Sciences, Hezarjerib Street, Isfahan 8174673461, Iran
    • ISSN:
      2090-4371
    • Accession Number:
      10.5402/2012/328945
    • Accession Number:
      86870757
  • Citations
    • ABNT:
      RISMANCHIAN, M. et al. Comparative Evaluation of Two Types of Immediately Loaded Implants Using Biomechanical and Histomorphometric Tests: An Animal Case Study. ISRN Dentistry, [s. l.], p. 1–6, 2012. DOI 10.5402/2012/328945. Disponível em: http://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=ddh&AN=86870757&custid=s8280428. Acesso em: 9 ago. 2020.
    • AMA:
      Rismanchian M, Movahedian B, Khalighinejad N, Badrian H, Razavi SM, Nekouie A. Comparative Evaluation of Two Types of Immediately Loaded Implants Using Biomechanical and Histomorphometric Tests: An Animal Case Study. ISRN Dentistry. January 2012:1-6. doi:10.5402/2012/328945
    • APA:
      Rismanchian, M., Movahedian, B., Khalighinejad, N., Badrian, H., Razavi, S. M., & Nekouie, A. (2012). Comparative Evaluation of Two Types of Immediately Loaded Implants Using Biomechanical and Histomorphometric Tests: An Animal Case Study. ISRN Dentistry, 1–6. https://doi.org/10.5402/2012/328945
    • Chicago/Turabian: Author-Date:
      Rismanchian, Mansour, Bijan Movahedian, Navid Khalighinejad, Hamid Badrian, Sayed Mohammad Razavi, and Afsaneh Nekouie. 2012. “Comparative Evaluation of Two Types of Immediately Loaded Implants Using Biomechanical and Histomorphometric Tests: An Animal Case Study.” ISRN Dentistry, January, 1–6. doi:10.5402/2012/328945.
    • Harvard:
      Rismanchian, M. et al. (2012) ‘Comparative Evaluation of Two Types of Immediately Loaded Implants Using Biomechanical and Histomorphometric Tests: An Animal Case Study’, ISRN Dentistry, pp. 1–6. doi: 10.5402/2012/328945.
    • Harvard: Australian:
      Rismanchian, M, Movahedian, B, Khalighinejad, N, Badrian, H, Razavi, SM & Nekouie, A 2012, ‘Comparative Evaluation of Two Types of Immediately Loaded Implants Using Biomechanical and Histomorphometric Tests: An Animal Case Study’, ISRN Dentistry, pp. 1–6, viewed 9 August 2020, .
    • MLA:
      Rismanchian, Mansour, et al. “Comparative Evaluation of Two Types of Immediately Loaded Implants Using Biomechanical and Histomorphometric Tests: An Animal Case Study.” ISRN Dentistry, Jan. 2012, pp. 1–6. EBSCOhost, doi:10.5402/2012/328945.
    • Chicago/Turabian: Humanities:
      Rismanchian, Mansour, Bijan Movahedian, Navid Khalighinejad, Hamid Badrian, Sayed Mohammad Razavi, and Afsaneh Nekouie. “Comparative Evaluation of Two Types of Immediately Loaded Implants Using Biomechanical and Histomorphometric Tests: An Animal Case Study.” ISRN Dentistry, January 2012, 1–6. doi:10.5402/2012/328945.
    • Vancouver/ICMJE:
      Rismanchian M, Movahedian B, Khalighinejad N, Badrian H, Razavi SM, Nekouie A. Comparative Evaluation of Two Types of Immediately Loaded Implants Using Biomechanical and Histomorphometric Tests: An Animal Case Study. ISRN Dentistry [Internet]. 2012 Jan [cited 2020 Aug 9];1–6. Available from: http://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=ddh&AN=86870757&custid=s8280428